Item |
Characteristics |
|
Operating
Temperature Range(oC) |
-55-+105 |
|
Rated Voltage Range (V) |
6.3~35 |
|
Nominal
capacitance range (uF) |
1~100 |
|
Capacitance Tolerance(20oC,
120Hz) |
+/-20% |
|
Leakage
Current (µA) |
I<=0.01CV or 3
whichever is greater.
C: Nominal Capacitance (µF) V: Rated Voltage (V)
|
|
Dissipation Factor(20oC,120Hz) |
|
Rated
voltage (v) |
6.3 |
10 |
16 |
25 |
35 |
|
D.F. |
0.22 |
0.20 |
0.18 |
0.14 |
0.12 |
|
|
Temperature
Stability(120Hz) |
|
Rated
voltage (v) |
6.3 |
10 |
16 |
25 |
35 |
|
Impedance
Ratio:
z-55oC/z+20oC
|
4 |
4 |
3 |
3 |
3 |
|
|
Load
Life(+105oC) |
|
Time |
2000hours |
|
Leakage
current |
Not
more than the specified value. |
|
Capacitance
change |
within+/-20%
of initial value |
|
Dissipation |
Not
more than 200% of the specified value. |
|
|
Shelf
Life(+105oC) |
|
Time |
500hours |
|
Leakage
current |
Not
more than the specified value. |
|
Capacitance
change |
within+/-20%
of initial value |
|
Dissipation |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for 30 minutes,
24 to 48 hours before measurement.
|