Item |
Characteristics |
|
Operating Temperature Range(oC) |
-40~+85 |
|
Rated Voltage Range (V) |
4~100 |
|
Nominal capacitance range(uF) |
0.1~470 |
|
Capacitance Tolerance(20oC,
120Hz) |
+/-20% |
|
Leakage Current (µA) |
I<=0.01CV or 3
whichever is greater. (at 20oC,after 2 minutes)
C: Nominal Capacitance (µF), V:
Rated Voltage (v) |
|
Dissipation Factor(20oC120Hz) |
|
Rated voltage (v) |
4 |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
|
D.F. |
0.35 |
0.24 |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
0.08 |
0.08 |
|
|
Temperature Stability (120Hz) |
|
Rated voltage (v) |
4 |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
|
Impedance ratio |
z-25oC/Z+20oC |
6 |
4 |
3 |
2 |
|
z-40oC/Z+20oC |
16 |
10 |
8 |
6 |
4 |
|
|
Load Life(+85oC) |
|
Time |
1000hours. |
|
Leakage current |
Not more than the specified
value |
|
Capacitance change |
within+/-20% of initial
value |
|
Dissipation factor |
Not more than 200% of the
specified value. |
|
|
Shelf Life (+85oC) |
|
Time |
500hours. |
|
Leakage current |
Not more than the specified
value |
|
Capacitance change |
within+/-20% of initial
value |
|
Dissipation factor |
Not more than 200% of the
specified value. |
After test: Rated
voltage to be applied for 30 minutes, 24 to 48 hours
before measurement. |